{"product_id":"vertiv-rdu501-infrastructure-gateway-for-data-center-monitoring","title":"Vertiv RDU501 Infrastructure Gateway for Data Center Monitoring","description":"\u003cdiv\u003e\n\u003ch1\u003eVertiv Liebert RDU501 Intelligent Infrastructure Gateway\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eVertiv Liebert RDU501\u003c\/strong\u003e is an intelligent infrastructure management solution designed for computer rooms and small to mid-size data centers. This \u003cstrong\u003epremium gateway appliance\u003c\/strong\u003e allows data center administrators to monitor environmental conditions and critical infrastructure including \u003cstrong\u003eUPS systems, precision cooling units, generator sets\u003c\/strong\u003e, and other mission-critical equipment. With its built-in web server, automated IT server shutdown, and out-of-band management capabilities, the RDU501 delivers complete control over your data center infrastructure.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Infrastructure Monitoring\u003c\/strong\u003e: Collects data from environmental sensors via Modbus 485, SNMP, dry contacts, and analog signals for real-time visibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIT Server Management\u003c\/strong\u003e: Connect up to 40 IT servers via IPMI v2.0 for remote monitoring, startup, shutdown, and out-of-band serial console access\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Web Server\u003c\/strong\u003e: Intuitive web-based interface for configuration, monitoring, and control accessible from anywhere\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated Server Shutdown\u003c\/strong\u003e: Intelligent automated IT server shutdown functionality protects critical equipment during power events\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Connectivity\u003c\/strong\u003e: Four Gigabit Ethernet ports, one fiber port, four RS-232\/485 serial ports, USB ports, and HDMI outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable Design\u003c\/strong\u003e: Four hot-swappable expansion slots support optional cards for additional I\/O and communication interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIntelligent Environmental Monitoring\u003c\/h2\u003e\n\u003cp\u003eThe RDU501 provides comprehensive environmental monitoring capabilities essential for maintaining optimal data center conditions. Monitor \u003cstrong\u003etemperature, humidity, water leaks, smoke, door contacts\u003c\/strong\u003e, and other environmental parameters in real time. The system supports multiple temperature and humidity sensors, digital input sensors including door sensors, water leak detection, smoke sensors, motion sensors, and vibration sensors. With its robust sensor integration, the RDU501 helps identify potential issues early, enabling proactive maintenance and significantly reducing the risk of downtime.\u003c\/p\u003e\n\n\u003ch2\u003eComplete Infrastructure Management\u003c\/h2\u003e\n\u003cp\u003eDesigned as an upgrade to the Liebert RDU-A G2, the RDU501 integrates easily within a \u003cstrong\u003e19-inch standard rack\u003c\/strong\u003e with its compact \u003cstrong\u003e43.5mm height\u003c\/strong\u003e. The appliance enables users to monitor the performance of all IT assets including thermal management units, UPS systems, and generator sets. Advanced features include video surveillance integration, access control management, remote door opening, power management with energy consumption tracking, and historical data logging with graphical alarm reports.\u003c\/p\u003e\n\n\u003ch2\u003eAdvanced IT Management Functions\u003c\/h2\u003e\n\u003cp\u003eBeyond environmental monitoring, the RDU501 delivers powerful IT management capabilities. Connect and manage up to 40 servers through \u003cstrong\u003eIPMI v2.0\u003c\/strong\u003e interfaces, providing full visibility and control. The out-of-band management features ensure you maintain access even during network outages. Serial console access enables direct server management, while the automated shutdown functionality protects servers during extended power events. Integration with Vertiv's \u003cstrong\u003eTrellis Smart InfraSight\u003c\/strong\u003e platform provides consolidated monitoring across multiple RDU501 units for enterprise-wide visibility.\u003c\/p\u003e\n\n\u003ch2\u003eReliable Fanless Design\u003c\/h2\u003e\n\u003cp\u003eThe RDU501 utilizes \u003cstrong\u003enatural cooling without fans\u003c\/strong\u003e, dramatically improving device reliability, reducing maintenance requirements, and enabling operation in dusty environments across a wide temperature range. This fanless design makes the unit ideal for edge deployments in remote locations such as BTS sites, network closets, and small server rooms where maintenance access may be limited.\u003c\/p\u003e\n\n\u003ch2\u003eUniversal Connectivity\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFour 10\/100\/1000M Gigabit Ethernet ports with one 1000M fiber port\u003c\/li\u003e\n\u003cli\u003eFour independent RS-232\/485 serial ports (self-adaptive)\u003c\/li\u003e\n\u003cli\u003eFour USB-A ports for keyboard, mouse, or USB modem connectivity\u003c\/li\u003e\n\u003cli\u003eTwo HDMI ports for local display\u003c\/li\u003e\n\u003cli\u003eFour digital input ports for dry contact sensors\u003c\/li\u003e\n\u003cli\u003eTwo relay output ports for alarm or control functions\u003c\/li\u003e\n\u003cli\u003eFour hot-swappable expansion slots for EXP8COM, EXP8DIAI, EXP8DOAO, and EXP2DI6DO cards\u003c\/li\u003e\n\u003cli\u003eDual isolated power inputs for redundancy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe Vertiv RDU501 is ideal for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall to mid-size data centers requiring comprehensive monitoring\u003c\/li\u003e\n\u003cli\u003eComputer rooms and server closets\u003c\/li\u003e\n\u003cli\u003eRemote infrastructure sites (BTS, network edge locations)\u003c\/li\u003e\n\u003cli\u003eIndustrial control environments requiring environmental monitoring\u003c\/li\u003e\n\u003cli\u003eMedical facilities with temperature-sensitive equipment or pharmaceutical storage\u003c\/li\u003e\n\u003cli\u003eIntegration with Building Management Systems (BMS) and DCIM platforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eCertifications and Compliance\u003c\/h2\u003e\n\u003cp\u003eThe RDU501 satisfies \u003cstrong\u003eCE, UL, FCC, and RoHS R10\u003c\/strong\u003e standards. Dust compliance meets indoor requirements of GR-63 for telecommunications environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRDU501 intelligent monitoring unit\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning manual\u003c\/li\u003e\n\u003cli\u003e19-inch rack mounting ears\u003c\/li\u003e\n\u003cli\u003eRDU line card\u003c\/li\u003e\n\u003cli\u003ePower cable (IEC60320 C13 to C14, 2000mm, EU standard)\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFull Specifications\u003c\/h2\u003e\n\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Mounting\u003c\/td\u003e\n\u003ctd\u003e19-inch standard rack, 1U height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e43.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eFanless (natural cooling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eWide temperature range supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eDust compliant with GR-63 indoor requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eIndoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eNetwork and Communication\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e4 × 10\/100\/1000M Gigabit Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Port\u003c\/td\u003e\n\u003ctd\u003e1 × 1000M fiber optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e4 × RS-232\/485 (self-adaptive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Ports\u003c\/td\u003e\n\u003ctd\u003e4 × USB-A type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo Output\u003c\/td\u003e\n\u003ctd\u003e2 × HDMI ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, Modbus 485, SNMP, IPMI v2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eI\/O and Expansion\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 ports (12 sensors supported by default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e2 ports (DO1, DO2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Slots\u003c\/td\u003e\n\u003ctd\u003e4 hot-swappable slots for optional cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Cards\u003c\/td\u003e\n\u003ctd\u003eEXP8COM, EXP8DIAI, EXP8DOAO, EXP2DI6DO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eIT Management\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eServer Connections\u003c\/td\u003e\n\u003ctd\u003eUp to 40 IT servers via IPMI v2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Devices\u003c\/td\u003e\n\u003ctd\u003eUp to 32 console devices supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Features\u003c\/td\u003e\n\u003ctd\u003eOut-of-band management, serial console access, automated server shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Inputs\u003c\/td\u003e\n\u003ctd\u003eDual isolated power inputs for redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connector\u003c\/td\u003e\n\u003ctd\u003eIEC60320 C14 inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eSoftware and Integration\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eBuilt-in web server with secure HTTPS access\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Protocols\u003c\/td\u003e\n\u003ctd\u003eHTTP, HTTPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration\u003c\/td\u003e\n\u003ctd\u003eCompatible with Trellis Smart InfraSight, BMS, and DCIM systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile App Support\u003c\/td\u003e\n\u003ctd\u003eYes (HTTPS connection required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eMonitoring Capabilities\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sensors\u003c\/td\u003e\n\u003ctd\u003eTemperature, humidity, water leak, smoke, motion, vibration, door contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrastructure Monitoring\u003c\/td\u003e\n\u003ctd\u003eUPS, precision cooling, generators, PDUs, thermal management units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Collection\u003c\/td\u003e\n\u003ctd\u003eModbus 485, SNMP, dry contacts, analog signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHistorical Records\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 energy consumption history records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, FCC, RoHS R10, GR-63 (dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eSpecifications are sourced from the manufacturer product page and may be updated.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Vertiv","offers":[{"title":"Default Title","offer_id":43731169574990,"sku":"PA-VERTIVRDU501","price":3940.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0676\/3134\/9838\/files\/RDU501_Q.jpg?v=1778213863","url":"https:\/\/projectorsaustralia.com.au\/products\/vertiv-rdu501-infrastructure-gateway-for-data-center-monitoring","provider":"Projectors Australia","version":"1.0","type":"link"}