Vertiv Geist Switched Outlet Level Monitoring Rack PDU with Remote Control

    Description

    Vertiv Geist Switched Outlet Level Monitoring Rack PDU

    The Vertiv Geist Switched Outlet Level Monitoring Rack PDU delivers comprehensive power management for data centers and IT infrastructure with granular outlet-level monitoring and remote switching capabilities. This intelligent rack power distribution unit tracks power consumption data for all connected equipment while providing the ability to remotely turn on, turn off, or reboot individual outlets. Perfect for data centers, server rooms, network closets, and enterprise IT environments, this switched PDU helps prevent circuit overloads, maximise uptime, and reduce costly on-site service calls.

    Why You'll Love It: Key Features

    • Individual Outlet Level Monitoring: Track granular power consumption data for every connected device with real-time metrics including voltage, amperage, watts, power factor, and kilowatt hours
    • Remote Outlet Switching: Remotely turn off receptacles to avoid accidental overloads or power cycle equipment to reboot unresponsive critical IT equipment without sending technicians on-site
    • Max Group Amps Protection: Set thresholds for maximum amperage to prevent circuit overload with an extra layer of protection
    • Hot-Swappable Monitoring Device: Upgrade technology on the fly without replacing the entire power strip as business needs change
    • Environmental Monitoring: Two sensor ports track temperature, airflow, humidity, dew point, and additional environmental variables via optional sensors
    • Secure Web Interface: Monitor remote conditions and manage power distribution through a secure web interface with HTTP and HTTPS protocols, flexible access rights, and up to three account levels

    Intelligent Power Management for Maximum Uptime

    This switched rack PDU provides real-time power consumption metrics accessible both at the rack via a local LED display and remotely via secure web interface. The embedded monitoring device tracks voltage, real power, apparent power, power factor, amperage, and kilowatt hours, enabling users to balance loads, evaluate energy usage trends, and ensure maximum uptime. With outlet-level switching, data center managers can remotely manage receptacles to avoid accidental overloads or reboot unresponsive IT equipment, significantly reducing downtime and service costs.

    Advanced Monitoring and Alerting

    Geist's switched PDUs feature proprietary real-time outlet status feedback that warns you if the actual status of outlets differs from what's being displayed, providing visual confirmation of relay state changes. The PDU can trigger escalating SNMP and email alarms if power or environmental levels fall outside specified parameters. Visible Light Communication (VLC) technology allows you to gather comprehensive power data at the palm of your hand using the Vertiv VLC mobile app without physically connecting to the PDU.

    Flexible Connectivity and Integration

    Available in a variety of electrical and receptacle configurations including NEMA 5-15R, NEMA 5-20R, IEC C13, and combination C13/C19 outlets, these PDUs support horizontal and vertical rack mounting options. Daisy chain Ethernet connectivity allows you to connect multiple PDUs without requiring expensive switch ports for each unit. The PDU supports comprehensive management protocols including SNMP v1/v2c/v3, HTTP/HTTPS, SSH, SMTP, DHCP, LDAP, NTP, RADIUS, TACACS+, Syslog, and JSON API for seamless integration into existing infrastructure management systems.

    Reliable Power Distribution

    Every Vertiv Geist rack PDU undergoes 100% individual testing for functionality and reliability to ensure units function as designed. North American units are UL listed in accordance with common data center and insurance provider requirements. Features include color-coded U-Lock receptacles by circuit for instant identification and secure cord retention to prevent accidental disconnections. Bi-stable latching relays significantly reduce idle power draw for energy efficiency.

    Applications

    • Data Centers: Monitor and manage power distribution across thousands of servers and switches with advanced outlet-level switching and monitoring
    • Financial Institutions: Ensure 24/7 uptime for online transaction systems with reliable power distribution and remote management
    • Enterprise IT Environments: Remotely power cycle unresponsive equipment and avoid accidental overloads without on-site visits
    • Network Closets and Server Rooms: Ideal for short racks and small cabinets with horizontal 1U form factor options
    • Hyperscale Environments: Support rack loads over 20 kVA with single-phase and three-phase configurations

    What's in the Box

    • Vertiv Geist Switched Outlet Level Monitoring Rack PDU
    • Power cord (length varies by model: typically 10ft/3m or 12ft/3.6m)
    • Rack mounting hardware
    • Interchangeable Monitoring Device (IMD) pre-installed
    • Quick start guide

    Full Specifications

    Power and Electrical

    Monitoring Level Switched with Outlet Level Monitoring
    Available Voltages 100-120V AC, 208V AC, 230V AC (model dependent)
    Available Currents 15A, 16A, 20A, 30A (model dependent)
    Power Capacity Range 1.4kW to 4.9kW (model dependent)
    Frequency 50/60 Hz
    Input Plug Types NEMA 5-15P, NEMA L5-20P, NEMA L6-30P, IEC C20 (model dependent)
    Outlet Types NEMA 5-15R, NEMA 5-20R, IEC C13, Combination C13/C19 (model dependent)
    Number of Outlets 8-12 outlets (model dependent)
    Monitoring Accuracy ±1% (ANSI & IEC Standards)

    Monitoring and Control

    Monitoring Type Input and outlet level power monitoring with outlet switching
    Metrics Tracked Voltage, current (amps), real power (watts), apparent power (VA), power factor, kilowatt hours (kWh)
    Outlet Control Remote on/off/reboot control per outlet
    Display Type Local high-visibility LED display (128×128 high-contrast LCD on select models)
    Display Features Intelligent orientation sensor adjusts screen for horizontal or vertical installation
    Environmental Monitoring Two sensor ports for optional temperature, humidity, dew point, airflow sensors
    Max Group Amps Feature Yes - user-definable threshold for maximum amperage protection
    Outlet Status Verification Real-time feedback with relay state confirmation

    Network and Connectivity

    Network Interface Dual RJ-45 Ethernet ports (10/100 Mb full duplex)
    Daisy Chaining Yes - fault-tolerant daisy chain up to 50 devices
    Supported Protocols SNMP v1/v2c/v3, HTTP, HTTPS, SSH, SMTP, SMTPS, DHCP, LDAP, NTP, RADIUS, TACACS+, RSTP, Syslog, IPv4, IPv6
    Management Interface JSON-based Web GUI, JSON API, Command-line interface via SSH
    Security Up to three user access account levels, secure boot with hardware-based trust anchor
    VLC Technology Visible Light Communication for mobile app monitoring via Vertiv rPDU Scanner app

    Physical Specifications

    Form Factor 1U horizontal rack mount or 0U vertical rack mount (model dependent)
    Typical Dimensions (1U Horizontal) 17" H × 1.7" W × 12" D
    Typical Weight 14 lbs / 6.4 kg (varies by model)
    Finish Black powder coat (color options available - contact sales)
    Receptacle Features Color-coded U-Lock receptacles by circuit
    Mounting Standard 19" rack compatible, cabinets and racks

    Features and Technology

    Hot-Swappable IMD Yes - Interchangeable Monitoring Device is field upgradeable and hot-swappable
    Bi-Stable Latching Relays Yes - reduces idle power draw
    Power Sequencing Time delays to define power up/down order and avoid circuit overload
    100% Testing Every unit individually tested for functionality and reliability
    Operating Temperature Up to 60°C for high temperature environments (Grade 60°C models)

    Compliance and Warranty

    Certifications UL Listed, c-UL Listed, FCC Part 15 Class A, RoHS Compliant, TAA Compliant (select models)
    Safety Standard UL 62368-1
    Warranty 3-year standard warranty (upgradeable to 5 years with product registration within 120 days)

    Specifications are sourced from the manufacturer product page and may be updated. Multiple models available with varying electrical configurations, outlet counts, and mounting options. Contact us for assistance selecting the right model for your application.

    Product form

    Vertiv Geist Switched Outlet Level Monitoring Rack PDU with Remote Control

      $3,201.95

      In Stock - Express Post Delivery Available (1-2 Business Days)  Mid weeks
      Monday to Friday we offer Express Post delivery
      Weekends
      We offer no delivery on weekends

        • Guaranteed secure & safe checkout.

          paypal
        • Free shipping on all orders

          Description

          Vertiv Geist Switched Outlet Level Monitoring Rack PDU

          The Vertiv Geist Switched Outlet Level Monitoring Rack PDU delivers comprehensive power management for data centers and IT infrastructure with granular outlet-level monitoring and remote switching capabilities. This intelligent rack power distribution unit tracks power consumption data for all connected equipment while providing the ability to remotely turn on, turn off, or reboot individual outlets. Perfect for data centers, server rooms, network closets, and enterprise IT environments, this switched PDU helps prevent circuit overloads, maximise uptime, and reduce costly on-site service calls.

          Why You'll Love It: Key Features

          • Individual Outlet Level Monitoring: Track granular power consumption data for every connected device with real-time metrics including voltage, amperage, watts, power factor, and kilowatt hours
          • Remote Outlet Switching: Remotely turn off receptacles to avoid accidental overloads or power cycle equipment to reboot unresponsive critical IT equipment without sending technicians on-site
          • Max Group Amps Protection: Set thresholds for maximum amperage to prevent circuit overload with an extra layer of protection
          • Hot-Swappable Monitoring Device: Upgrade technology on the fly without replacing the entire power strip as business needs change
          • Environmental Monitoring: Two sensor ports track temperature, airflow, humidity, dew point, and additional environmental variables via optional sensors
          • Secure Web Interface: Monitor remote conditions and manage power distribution through a secure web interface with HTTP and HTTPS protocols, flexible access rights, and up to three account levels

          Intelligent Power Management for Maximum Uptime

          This switched rack PDU provides real-time power consumption metrics accessible both at the rack via a local LED display and remotely via secure web interface. The embedded monitoring device tracks voltage, real power, apparent power, power factor, amperage, and kilowatt hours, enabling users to balance loads, evaluate energy usage trends, and ensure maximum uptime. With outlet-level switching, data center managers can remotely manage receptacles to avoid accidental overloads or reboot unresponsive IT equipment, significantly reducing downtime and service costs.

          Advanced Monitoring and Alerting

          Geist's switched PDUs feature proprietary real-time outlet status feedback that warns you if the actual status of outlets differs from what's being displayed, providing visual confirmation of relay state changes. The PDU can trigger escalating SNMP and email alarms if power or environmental levels fall outside specified parameters. Visible Light Communication (VLC) technology allows you to gather comprehensive power data at the palm of your hand using the Vertiv VLC mobile app without physically connecting to the PDU.

          Flexible Connectivity and Integration

          Available in a variety of electrical and receptacle configurations including NEMA 5-15R, NEMA 5-20R, IEC C13, and combination C13/C19 outlets, these PDUs support horizontal and vertical rack mounting options. Daisy chain Ethernet connectivity allows you to connect multiple PDUs without requiring expensive switch ports for each unit. The PDU supports comprehensive management protocols including SNMP v1/v2c/v3, HTTP/HTTPS, SSH, SMTP, DHCP, LDAP, NTP, RADIUS, TACACS+, Syslog, and JSON API for seamless integration into existing infrastructure management systems.

          Reliable Power Distribution

          Every Vertiv Geist rack PDU undergoes 100% individual testing for functionality and reliability to ensure units function as designed. North American units are UL listed in accordance with common data center and insurance provider requirements. Features include color-coded U-Lock receptacles by circuit for instant identification and secure cord retention to prevent accidental disconnections. Bi-stable latching relays significantly reduce idle power draw for energy efficiency.

          Applications

          • Data Centers: Monitor and manage power distribution across thousands of servers and switches with advanced outlet-level switching and monitoring
          • Financial Institutions: Ensure 24/7 uptime for online transaction systems with reliable power distribution and remote management
          • Enterprise IT Environments: Remotely power cycle unresponsive equipment and avoid accidental overloads without on-site visits
          • Network Closets and Server Rooms: Ideal for short racks and small cabinets with horizontal 1U form factor options
          • Hyperscale Environments: Support rack loads over 20 kVA with single-phase and three-phase configurations

          What's in the Box

          • Vertiv Geist Switched Outlet Level Monitoring Rack PDU
          • Power cord (length varies by model: typically 10ft/3m or 12ft/3.6m)
          • Rack mounting hardware
          • Interchangeable Monitoring Device (IMD) pre-installed
          • Quick start guide

          Full Specifications

          Power and Electrical

          Monitoring Level Switched with Outlet Level Monitoring
          Available Voltages 100-120V AC, 208V AC, 230V AC (model dependent)
          Available Currents 15A, 16A, 20A, 30A (model dependent)
          Power Capacity Range 1.4kW to 4.9kW (model dependent)
          Frequency 50/60 Hz
          Input Plug Types NEMA 5-15P, NEMA L5-20P, NEMA L6-30P, IEC C20 (model dependent)
          Outlet Types NEMA 5-15R, NEMA 5-20R, IEC C13, Combination C13/C19 (model dependent)
          Number of Outlets 8-12 outlets (model dependent)
          Monitoring Accuracy ±1% (ANSI & IEC Standards)

          Monitoring and Control

          Monitoring Type Input and outlet level power monitoring with outlet switching
          Metrics Tracked Voltage, current (amps), real power (watts), apparent power (VA), power factor, kilowatt hours (kWh)
          Outlet Control Remote on/off/reboot control per outlet
          Display Type Local high-visibility LED display (128×128 high-contrast LCD on select models)
          Display Features Intelligent orientation sensor adjusts screen for horizontal or vertical installation
          Environmental Monitoring Two sensor ports for optional temperature, humidity, dew point, airflow sensors
          Max Group Amps Feature Yes - user-definable threshold for maximum amperage protection
          Outlet Status Verification Real-time feedback with relay state confirmation

          Network and Connectivity

          Network Interface Dual RJ-45 Ethernet ports (10/100 Mb full duplex)
          Daisy Chaining Yes - fault-tolerant daisy chain up to 50 devices
          Supported Protocols SNMP v1/v2c/v3, HTTP, HTTPS, SSH, SMTP, SMTPS, DHCP, LDAP, NTP, RADIUS, TACACS+, RSTP, Syslog, IPv4, IPv6
          Management Interface JSON-based Web GUI, JSON API, Command-line interface via SSH
          Security Up to three user access account levels, secure boot with hardware-based trust anchor
          VLC Technology Visible Light Communication for mobile app monitoring via Vertiv rPDU Scanner app

          Physical Specifications

          Form Factor 1U horizontal rack mount or 0U vertical rack mount (model dependent)
          Typical Dimensions (1U Horizontal) 17" H × 1.7" W × 12" D
          Typical Weight 14 lbs / 6.4 kg (varies by model)
          Finish Black powder coat (color options available - contact sales)
          Receptacle Features Color-coded U-Lock receptacles by circuit
          Mounting Standard 19" rack compatible, cabinets and racks

          Features and Technology

          Hot-Swappable IMD Yes - Interchangeable Monitoring Device is field upgradeable and hot-swappable
          Bi-Stable Latching Relays Yes - reduces idle power draw
          Power Sequencing Time delays to define power up/down order and avoid circuit overload
          100% Testing Every unit individually tested for functionality and reliability
          Operating Temperature Up to 60°C for high temperature environments (Grade 60°C models)

          Compliance and Warranty

          Certifications UL Listed, c-UL Listed, FCC Part 15 Class A, RoHS Compliant, TAA Compliant (select models)
          Safety Standard UL 62368-1
          Warranty 3-year standard warranty (upgradeable to 5 years with product registration within 120 days)

          Specifications are sourced from the manufacturer product page and may be updated. Multiple models available with varying electrical configurations, outlet counts, and mounting options. Contact us for assistance selecting the right model for your application.

          Not sure which projector to choose?

          Fill-out our quote request form and we will help you select the best option for your needs

          Returns & Delivery

          When will my order be delivered?

          Orders are usually dispatched within 1–2 business days. Standard delivery times are:

          • Metro areas: 2–4 business days
          • Regional areas: 3–7 business days
          • Remote areas: Up to 10 business days

          You’ll receive a tracking number by email once your order is shipped. If you haven’t received it within 2 business days, please contact us at admin@projectorsaustralia.com.au.

          Can I return my product?

          We accept change-of-mind returns within 28 days, as long as the item is in unused, saleable condition and in its original packaging. A 10% restocking fee applies. Return shipping is at the buyer’s expense.

          To begin a return, contact us at admin@projectorsaustralia.com.au to request a Return Authorisation Number.

          Read our full Returns Policy for more details.

          What can I do if my item (or part of it) is damaged?

          Please contact us at admin@projectorsaustralia.com.au within 24 hours of receiving your delivery. Include:

          • Your order number
          • A description of the issue
          • Clear photos of the damage or issue

          We’ll work quickly to resolve it through a refund, replacement, or repair in accordance with our policy and Australian Consumer Law.

          Recently viewed products

          Login

          Forgot your password?

          Don't have an account yet?
          Create account